Sign In | Join Free | My burrillandco.com
Home > Measuring Instrument >

Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material

    Buy cheap Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material from wholesalers
     
    Buy cheap Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material from wholesalers
    • Buy cheap Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material from wholesalers
    • Buy cheap Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material from wholesalers
    • Buy cheap Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material from wholesalers

    Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material

    Ask Lasest Price
    Brand Name : Altrasonic
    Model Number : HS-520A
    Certification : CE
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : 200 Set per month
    Delivery Time : 10 work days
    • Product Details
    • Company Profile

    Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material

    Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material


    Specifications:


    Specification
    Performance
    HS-520A
    Product featurePortable, 8inch screen, Full touch screen
    DimensionL24cm,W19cm,H10cm
    Frequency range1KHz~500kHz/1Mhz/hz
    Measurement IndexAll the parameters, the graph
    Measurement Accuracy< 0.5%
    Measurement Speed5s/one pass(600scan point) Adjustable
    Frequency Accuracy±10ppm
    Phase Resolution0.15 degree
    Environment Temperature10~40degree centigrade
    Impedance Range1Ω~1MΩ
    Frequency Step0.1Hz~any
    Power SupplyAC100V~AC250V,50~60Hz, 30W

    Description:


    For ultrasonic components measuring instrument, the most important is the admittance chart, logarithmic graph of the two graphics (the two graphics is the main method of qualified qualified), and more than a dozen parameters: resonance frequency Fs, the maximum conductance Gmax, bandwidth F2-F1, anti-resonance frequency Fp, quality factor Qm, free capacitance CT, dynamic resistance R1, dynamic inductance L1, dynamic capacitance C1, static capacitance C0, effective electromechanical coupling coefficient Keff.


    Characteristics:


    1. Large screen, full-screen touching, making the HS520A both HS70A-P(computer version) operating experience, and no cumbersome with a sense of computer operation.

    2. Relies on the new powerful ARM processor data processing capacity, HS520A measurement accuracy is much higher than HS70A-D (with display version), can achieve HS70A-P(computer version) level.

    3. Full-screen touch operation is more user-friendly, no longer need HS70A-D(own display version) a large number of physical buttons, thus operating instruments becomes extremely simple, the production size smaller, lighter and more portable.

    4. Connecting the computer to operate as HS70V-P. The software is fully compatible, the user are no longer familiar with software operation.

    5.HS520A was taken into account the needs of automated production line operation in the development time, reserved the 232interface with PLC communication and IO communication interface (replay input and output)

    6. HS520A operation is no longer based on Windows system, with long-term reliable operation capacity in the production line.


    Measuring:


    (Note: There are differences in the relevant characteristic data of different manufacturers)

    Measurement parameters: |Z|, |Y|, θ, R, X, G, B, L, C, D, Q can provide 12 parameter combinations

    Test frequency: 100Hz~40MHz (cable length: 0m)

    Vibrator level: 10mV~1Vrms (≤10MHz), 10mV~0.5Vrms (>10MHz); (UNKNOWN open), 3-bit resolution

    DC offset: 0~±40V, 10mV resolution

    Measurement terminal: 4-terminal configuration

    Measuring range and highest resolution

    Measurement parameter range maximum resolution

    Basic measurement accuracy: 0.17 [%]

    Level monitoring: 1mV~1 Vrms, 1μA~20mA

    Gain-phase measurement

    Measurement parameters: Tch/Rch (dB, linear ratio); Tch, Rch (V, dBm, dBv), θ (degrees, radians); Tch = measurement channel: Rch = reference channel, g = group delay

    10Hz~100MHz, 1mHz resolution

    Aperture frequency range: (group delay measurement) frequency interval 0.5 [%] ~ 100 [%]

    Oscillator level: -65dBm~+15dBm, 0.1dB resolution

    Measurement range: Tch/Rch: 0~±120dB, 0.001dB resolution; Tch, Rch: -107dBm~-5dBm (0dB attenuator), -87dBm~+15dBm, (20dB attenuator); 0.001dB, resolution: θ: ±180° (using phase scale extension function, continuous display of phase) 0.01° resolution; g: 0.1 ns~1 s, 0.1 ns resolution

    Basic measurement accuracy: Tch/Rch: 0.1dB, 0.5°; Tch, Rch: 0.35dBm

    Level Monitoring: Monitors the input level of the reference and test channels in dBm, dBV and V.


    Detailed Images:


    Ultrasonic Quality Factor And Impedance Analyzing For Ceramic MaterialUltrasonic Quality Factor And Impedance Analyzing For Ceramic MaterialUltrasonic Quality Factor And Impedance Analyzing For Ceramic Material


    Quality Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hangzhou Altrasonic Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)